EQUINOX
EKİNOKS-N Simulator & Diagnostic System sends NMEA 0183 sentences that can be defined and edited by the user over user-configurable serial ports and Ethernet TCP, UDP connections. It can generate sentences provided by various navigation devices that produce data according to the NMEA/IEC61162 protocol and send these sentences to one or more receivers. With the capabilities provided by EKINOKS-N, users can easily test their own systems and devices and solve many problems they will encounter in the field beforehand. The system enables all devices used in navigation systems to be created and used in a virtual way and to monitor, record and replay the data flowing between devices on the map.
Technical Specifications
Highlights
Technical Specifications
- Ability to create data of each device, select sentences to be produced
- Ability to determine separate serial port, communication speed, transmission frequency for each device
- Ability to define Ethernet TCP/UDP for each device
- Ability to define live simulation for each device
- Ability to set custom TalkerID
- Ability to create custom HDLC data
- Ability to save sent and received information to a file
- Display of information coming with the analyzer and display of incorrect information
- Coordinated operation of all virtual devices (Start-stop)
- NMEA Terminal screen for general use
- Binary data transmission, reception and display (in decimal and hexadecimal)
- User-friendly interface
- All device settings can be saved and restored.
- Broadcast and monocast over TCP or UDP.
- TCP/UDP terminal for general use
- High speed URI-10 interface unit
- Transmission up to 3 Mbaud
- Simulated/Analyzed Devices:
o GPS (GLL, RMC, VTG, ZDA, GGA, GSA, GSV, XTE, RMB, DTM)
o Gyro (HDT,HDG,HDM,ROT,TSS1,HRP)
o Magnetic compass
o ECHO Sounder (DPT,DBT,DBK,DBS)
o EM Log (VHW,VLW,VBW)
o Anemometer (MWD, MWV, VWR, VWT, MTW)
o AIS (Class A, Class B araçlar
o Radar (TLL, TTM, OSD)
o Special Devices
Highlights
- Ability to create navigation systems data
- Separate serial port, communication speed, sending frequency
- Ethernet TCP/UDP definition for each system
- Ability to set custom TalkerID
- Ability to create custom HDLC data
- Incorrect, missing data, defective unit isolation with Analyzer
- Ability to monitor NMEA terminal screen data
- Binary data transmission, reception and display
- TCP/UDP terminal for general use
- Playback and data analysis on interactive map
ekinoks_01-768x378
ekinoks_03-768x378
ekinoks_04-768x378
ekinoks_05-768x378
ekinoks_06-768x378
ekinoks_alt_banner-768x300