MILITARY FAN
SPECIFICATIONS OF THE FANS
- The fans are designed to meet the required military standards (MIL-STD-810, MIL-STD-461, MIL-B-28873) and harsh ambient conditions.
- The fans are designed in accordance with ISO 1940-1 standards for the required balances.
- The case and rotor parts of the fans are made of AL6061-T6 material with five axis CNC machine and stainless steel is used as shaft material.
- Two high precision ball bearings with integrated lubricant which is suitable for operation at -54 degrees Celsius with stainless steel cover are used in the fans.
- All fans are coated in accordance with MIL-A-8625F and MIL-C-5541 standards.
- The fans receive their power from brushless DC or AC motors which are designed by ANOVA.
- The fans have high efficiency, vector-controlled drives which are designed by ANOVA.
- The fans have speed information and error signal feedback options.
- Performance tests of the fans are carried out within ANOVA in accordance with AMCA-210
- Standard
ENVIRONMENTAL SPECIFICATIONS
These fans can be designed to meet the requirements of MIL-STD-704 and the
following requirements of MIL-STD-810G-CHG-1;
- Op. Temperature: Method 502.6 Procedure II, 501.6 Procedure II
- St. Temperature: Method 502.6 Procedure I, 501.6 Procedure I
- Acceleration: Method 513.7 Procedure II
- Vibration: Method 514.7 Procedure I
- Shock: Method 516.7 Procedure I
- Salt Fog: Method 509.6
- Rain: Method 506.6 Procedure I
- Fungus: Method 508.7
- Humidity: Method 507.6 Procedure II
- Altitude: Method 500.6 Procedure II
- Temp. Shock: Method 503.6 Procedure I
- Fluid Contamination: Method 504.2